ESEN
GEOFUEGO

Methodology

The system has three components: two indices — one daily, one seasonal — and the satellite detection record that tests them against the ground.

Sources and standards

Index: Van Wagner, C.E. (1987), Development and Structure of the Canadian Forest Fire Weather Index System, Canadian Forestry Service, Forestry Technical Report 35 — implementation verified against the official Canadian system package (CFFDRS). Danger classes: the five classes of Argentina's National Fire Management Service (SNMF), with statistical thresholds by sub-region estimated by GEOFUEGO (SNMF does not publish its own). Live FWI meteorology: Open-Meteo (global models), each province's historical fire zones (FIRMS 2012–2024), with 92 days of spin-up for the drought codes and the initial DC taken from ERA5; 24, 48 and 72 h outlook with the forecast meteorology of the same models. Hotspots: NASA FIRMS / VIIRS (375 m). Provincial boundaries: IGN. Validation: 2019–2023 daily series for the Paraná Delta cross-checked against historical detections. GeoFuego Index (GFI) 3.0: ONI (NOAA/CPC) × FIRMS detections 2001–2025 (MODIS + VIIRS, intra-sensor anomalies); drought term: DC code (CFFDRS) over the ERA5 reanalysis of the Copernicus Climate Data Store (Hersbach et al., 2020; ERA5T in the live product), across 115 fire zones derived from the FIRMS archive. Antecedent: Chen, Y. et al. (2011), Forecasting Fire Season Severity in South America Using Sea Surface Temperature Anomalies, Science 334, 787–791 (doi:10.1126/science.1209472).

Map credits: satellite imagery and basemaps © Esri, Vantor, Earthstar Geographics, HERE, Garmin and the GIS user community; place names and roads © OpenStreetMap contributors; provincial boundaries: Instituto Geográfico Nacional (IGN); daily and night satellite layers: NASA GIBS.

Documented case: the fire over the native forest of western Formosa (September 2026) DOI 10.5281/zenodo.23602671 — satellite reconstruction of the event, together with Copernicus.

Published method

The full GeoFuego Index (GFI) method is published and verifiable: frozen calibration (3.0.0) for Argentina and Indonesia, reference rule engine, and the scripts that reproduce every table and figure of the manuscript. The published calibration file is the one the product loads. The manuscript — “Seasonal fire-risk skill from ENSO phase and zone-level accumulated drought: a regional-scale categorical indicator transferred from Argentina to Indonesia” — was submitted on 12 Nov 2026 to Natural Hazards and Earth System Sciences (NHESS, EGUSPHERE-2026-7057); it is neither accepted nor published.

Method packagedoi:10.5281/zenodo.24164911 (Zenodo · v1.2.0, the current one and the manuscript's · CC BY 4.0 + MIT). All versions: 10.5281/zenodo.23017739
Indonesiageofuego.com.ar/indonesia (Sumatra and Kalimantan; same v1.2.0 package)
Repositorygithub.com/germankovacevic-lab/gfi-method-package
Public APIingesta.geofuego.com.ar/api/gfi/ar · /api/gfi/id (current GFI 3.0 by region and province, Argentina and Indonesia; JSON, no authentication)

Versions

PackageDateTerritoriesMeteorologyRules
1.2.0 · current
zenodo.24164911
2026-11Argentina + Indonesia, seven climatic regionsERA5 (Copernicus CDS) in both territories3.0: ENSO signal only where the bootstrap interval of the phase ratio excludes 1; HIGH requires drought; regional extent with LOYO thresholds; the unit is the region
1.1.0 · superseded
zenodo.23987348
2026-11-05+ Sumatra and Kalimantan (75 zones)Argentina as 1.0; Indonesia ERA5 (mixed sources)as 1.0, unchanged
1.0.0 · superseded
zenodo.23017740
2026-09-28Argentina (116 zones)Open-Meteo archive (ERA5 blended with other models)2.2.0: fixed ENSO cut-offs, Patagonia inverse, national two-thirds rule — all withdrawn in 3.0

Prospective registry: every level published since deployment (2026-09-27) is out of sample and publicly inspectable, and is scored against the version in force at the time of its publication. The calibration is frozen between seasons.

Another region, another country?

The method is scalable: the data sources (NASA FIRMS, ERA5, ONI) are global and the architecture is not tied to Argentina. For each country or region, its own fire zones are derived from the local satellite archive and the index is calibrated against its history — the same published pipeline, with a tailored calibration. The ENSO signal on fire is documented for all of South America (Chen et al. 2011, Science).

Already proven outside Argentina — Indonesia (Sumatra and Kalimantan): the same method, without tuning, derived 75 fire zones and found the inverse-sign ENSO signal on its own: with El Niño three months earlier, August–October fire reaches 7.7× its median in southern Sumatra. The 2026 season, out of sample, came in at 7.8×. Code and data: Zenodo v1.2.0.

Interested in the system for your country, state or region? Write to us: hola@geofuego.com.ar

This index is a danger signal for prevention — it is not an official alert and does not replace Argentina's National Fire Management Service (SNMF) or civil-defense authorities. For an active fire, call 100 (Firefighters) or 911.
GEOFUEGO · satellite monitoring — a product by AgentNeo.